SQ3140B / SQ3200B / SQ3300B
The Kubota SQ3140 is a premium compact three phase four pole diesel generator with a capacity of 14kVA at 1500RPM, the Kubota SQ-3200B-AU-B is super quiet with a capacity of 20kVA at 1500RPM and the SQ-3300B-AU-B diesel generator comes with 30kVA at 1500RPM capacity. These diesel generators are fully sound attenuated for super quiet operation. There’s no need to worry about engine fuel leakages, as both the SQ-3200B and SQ-3300B are fully bunded.
Product Features
1
2
3
4
5
6
7
8
Engines
The Kubota SQ-3140B-AU-B is a premium compact three-phase four pole diesel generator with a capacity of 14kVA at 1500RPM and is available to work under a single phase 240 voltage and run a current (A) of 12.5 amps or a 3 phase 415 voltage and a run a current of 19.5 amps per phase. Powered by Kubota’s D1703 fuel efficient, water cooled diesel engine.
The Kubota SQ-3200B-AU-B is a premium compact three-phase four pole diesel generator with a capacity of 20kVA at 1500RPM and is available to work under a single phase 240 voltage and run a current (A) of 18.1 amps or a 3 phase 415 voltage and a run a current of 27.8 amps per phase. Powered by Kubota’s renowned V2203 water cooled diesel engine.
The Kubota SQ-3300B-AU-B is a premium compact three-phase four pole diesel generator with a capacity of 30kVA at 1500RPM and is available to work under a single phase 240 voltage and run a current (A) of 27.1 amps or a 3 phase 415 voltage and a run a current of 41.7 amps per phase. Powered by Kubota’s extra reliable V3300 water cooled diesel engine.
Kubota diesel engines incorporate a TVCS combustion system which improve air/fuel mixture, resulting in cleaner emissions. All models are available with automatic shutdown of the engine if abnormal conditions are detected.
Components
Brushless, self-exciting type alternator delivers reliable, high-quality power. Centre lifting lugs and fork lift slots ensure easy transportation. Single sided access for quick inspection and easy maintenance. All rotating parts enclosed in a sturdy lockable enclosure.
Runtimes
The SQ-3140B-AU-B diesel generator has a running range time of 24.5 hours at three quarter load, while the Kubota SQ-3200B-AU-B diesel generator delivers a run range time of 25 hours at three quarter load. The SQ-3300B-AU-B diesel generator has a running range time of 24 hours at three quarter load.
Solar applications
Fully bunded for your peace of mind in case of engine failure or fuel leaks, the Kubota SQ-3140, SQ-3200 and SQ-3300 are factory fitted with digital controller and 2-wire auto start model for solar applications. Power when you need it.
Safety
The Residual Current Device will be factory fitted and this will offer a high level of personal protection to the operator from electrical shock and provide high levels of protection from potential electrical fires. The factory fitted circuit breakers offer protection against suddenly large overloads of electrical flow and large power loads potentially destroying electrical equipment. The circuit breakers offer increased safety.
Base mounted fuel tank
The SQ Series is equipped with a large capacity bottom mounted fuel tank to prevent fuel spills inside the enclosure (Bunded 110%). The locking fuel door is placed to avoid damage and simplify refuelling
Control panel
Features – Emergency stop button, waterproof enclosure. Standard with manual key start and hard wire connection to output circuit breaker. Standard with Digital Control Panel- DSE4520. Optional weatherproof outlets available.
Receptacles
Four switches and four receptacles (IP66) with two additional spaces. Located below the switches (within the skid rail) are two tow points to aide in handling.
Engines
The Kubota SQ-3140B-AU-B is a premium compact three-phase four pole diesel generator with a capacity of 14kVA at 1500RPM and is available to work under a single phase 240 voltage and run a current (A) of 12.5 amps or a 3 phase 415 voltage and a run a current of 19.5 amps per phase. Powered by Kubota’s D1703 fuel efficient, water cooled diesel engine.
The Kubota SQ-3200B-AU-B is a premium compact three-phase four pole diesel generator with a capacity of 20kVA at 1500RPM and is available to work under a single phase 240 voltage and run a current (A) of 18.1 amps or a 3 phase 415 voltage and a run a current of 27.8 amps per phase. Powered by Kubota’s renowned V2203 water cooled diesel engine.
The Kubota SQ-3300B-AU-B is a premium compact three-phase four pole diesel generator with a capacity of 30kVA at 1500RPM and is available to work under a single phase 240 voltage and run a current (A) of 27.1 amps or a 3 phase 415 voltage and a run a current of 41.7 amps per phase. Powered by Kubota’s extra reliable V3300 water cooled diesel engine.
Kubota diesel engines incorporate a TVCS combustion system which improve air/fuel mixture, resulting in cleaner emissions. All models are available with automatic shutdown of the engine if abnormal conditions are detected.
Components
Brushless, self-exciting type alternator delivers reliable, high-quality power. Centre lifting lugs and fork lift slots ensure easy transportation. Single sided access for quick inspection and easy maintenance. All rotating parts enclosed in a sturdy lockable enclosure.
Runtimes
The SQ-3140B-AU-B diesel generator has a running range time of 24.5 hours at three quarter load, while the Kubota SQ-3200B-AU-B diesel generator delivers a run range time of 25 hours at three quarter load. The SQ-3300B-AU-B diesel generator has a running range time of 24 hours at three quarter load.
Solar applications
Fully bunded for your peace of mind in case of engine failure or fuel leaks, the Kubota SQ-3140, SQ-3200 and SQ-3300 are factory fitted with digital controller and 2-wire auto start model for solar applications. Power when you need it.
Safety
The Residual Current Device will be factory fitted and this will offer a high level of personal protection to the operator from electrical shock and provide high levels of protection from potential electrical fires. The factory fitted circuit breakers offer protection against suddenly large overloads of electrical flow and large power loads potentially destroying electrical equipment. The circuit breakers offer increased safety.
Base mounted fuel tank
The SQ Series is equipped with a large capacity bottom mounted fuel tank to prevent fuel spills inside the enclosure (Bunded 110%). The locking fuel door is placed to avoid damage and simplify refuelling
Control panel
Features – Emergency stop button, waterproof enclosure. Standard with manual key start and hard wire connection to output circuit breaker. Standard with Digital Control Panel- DSE4520. Optional weatherproof outlets available.
Receptacles
Four switches and four receptacles (IP66) with two additional spaces. Located below the switches (within the skid rail) are two tow points to aide in handling.
Specifications
Name | SQ3140B | SQ3200B | SQ3300B |
---|---|---|---|
Fuel Type | Diesel | Diesel | Diesel |
Phase | Three | Three | Three |
Fuel Tank Capacity | 72 l | 100 l | 142 l |
Operating Hours @Full Load | 24.8 hours | 25 hours | 24 hours |
Starting System | Electric | Electric | Electric |
Weight | 780 kg | 915 kg | 1135 kg |
Sound Levels @7m | 61 dBA | 63 dBA | 64 dBA |
Dimensions | 1725 x 795 x 1095 mm | 1725 x 795 x 1180 mm | 1935 x 860 x 1310 mm |
Name | SQ3140B | SQ3200B | SQ3300B |
---|---|---|---|
Engine Model | D1703-EBG | V2203-EBG | V3300-EBG |
Engine Type | Vetical Water Cooled | Vertical Water Cooled | Vertical Water Cooled |
Displacement | 1647 cc | 1647 cc | 3318 cc |
No of Cylinders | 3 | 4 | 4 |
Bore & Stroke | 87 x 92.4 mm | 87 x 92.4 mm | 98 x 110 mm |
Rated Output | 13.6 kW | 18.4 kW | 26.8 kw |
RPM | 1500 rpm | 1500 rpm | 1500 rpm |
Name | SQ3140B | SQ3200B | SQ3300B |
---|---|---|---|
Type | Revolving Field | Revolving Field | Revolving Field |
Max Output | 15.4 kVA | 22 kVA | 33 kVA |
Rated Output | 14 kVA | 20 kVA | 30 kVA |
Voltage | 240/415 | 240/415 | 240/415 |
Frequently | 50 Hz | 50 Hz | 50 Hz |
Current | 19.5 Amps | 27.8 Amps | 41.7 Amps |
Power Factor | 0.8 | 0.8 | 0.8 |
Poles | 4 | 4 | 4 |
Voltage Regulation | AVR | AVR | AVR |