KJ-S130 / KJ-S230
The Kubota KJ-S130-AU-B generator features a four-pole, cabinet style, single-phase diesel generator with a capacity of 12.5kVA at 1500RPM, while the KJ-S230-AU-B generator is also a four-pole, full cabinet style, single-phase diesel generator with a capacity of 23kVA at 1500RPM. Both are available to work under 240 voltage, with a current (A) of 52.1 amps per phase for the Kubota KJ-S130 and 95.8 amps for the Kubota KJ-S230. That’s on the money for industrial, construction, mining and agricultural uses, to help getting the tough jobs done right. The Kubota KJ-S130-AU-B and the KJ-S230-AU-B diesel generator’s digital models also feature a 2-wire auto start for solar applications fitted as standard, providing power when you need it most. While the Kubota KJ-S130-AU-B diesel generator is backed by our powerful Kubota V2203 diesel engine – renowned worldwide for its extra reliability and efficiency, the KJ-S230-AU-B is powered by our world-renowned Kubota V3300 diesel engine, with a running range time of 8.8 hours at full load and. This therefore makes the Kubota KJ-S230-AU-B diesel generator the perfect solution to your business back-up power.
Product Features
1
2
3
4
5
6
Engine
The Kubota KJ-S130-AU-B diesel generator is backed by our powerful Kubota V2203 diesel engine and has a capacity of of 12.5kVA and 1500RPM. Available to work under a 415 voltage and run a current (A) of 25 amps per phase. The Kubota KJ-S230-AU-B generator and has a capacity of 23kVA at 1500RPM. Available to work under a 240 voltage and run a current (A) of 95.8 amps. All models are available with automatic shutdown of the engine if abnormal conditions are detected.
Components
Single sided access for quick inspection and easy maintenance. Sound attenuated enclosure effectively reduces all sound, including the muffler. Kubota’s original TVCS combustion system substantially reduces sound levels. Twin-point lifting eyes makes transportation easy.
Runtime
The KJ-S130-AU-B diesel generator has a running range time of 7 hours at full load, while the Kubota KJ-S230-AU-B diesel generator delivers a run range time of 8.8 hours at full load.
Solar applications
The Kubota KJ-S130 and KJ-S230-AU-B diesel generator also feature a 2-wire auto start for solar applications fitted as standard. Power when you need it.
Safety
The Residual Current Device will be factory fitted and this will offer a high level of personal protection to the operator from electrical shock and provide high levels of protection from potential electrical fires. The factory fitted circuit breakers offer protection against suddenly large overloads of electrical flow and large power loads potentially destroying electrical equipment. The circuit breakers offer increased safety.
Control panel
Digital Control Panel – DSE4520 (Remote Start 2 Wire).
Engine
The Kubota KJ-S130-AU-B diesel generator is backed by our powerful Kubota V2203 diesel engine and has a capacity of of 12.5kVA and 1500RPM. Available to work under a 415 voltage and run a current (A) of 25 amps per phase. The Kubota KJ-S230-AU-B generator and has a capacity of 23kVA at 1500RPM. Available to work under a 240 voltage and run a current (A) of 95.8 amps. All models are available with automatic shutdown of the engine if abnormal conditions are detected.
Components
Single sided access for quick inspection and easy maintenance. Sound attenuated enclosure effectively reduces all sound, including the muffler. Kubota’s original TVCS combustion system substantially reduces sound levels. Twin-point lifting eyes makes transportation easy.
Runtime
The KJ-S130-AU-B diesel generator has a running range time of 7 hours at full load, while the Kubota KJ-S230-AU-B diesel generator delivers a run range time of 8.8 hours at full load.
Solar applications
The Kubota KJ-S130 and KJ-S230-AU-B diesel generator also feature a 2-wire auto start for solar applications fitted as standard. Power when you need it.
Safety
The Residual Current Device will be factory fitted and this will offer a high level of personal protection to the operator from electrical shock and provide high levels of protection from potential electrical fires. The factory fitted circuit breakers offer protection against suddenly large overloads of electrical flow and large power loads potentially destroying electrical equipment. The circuit breakers offer increased safety.
Control panel
Digital Control Panel – DSE4520 (Remote Start 2 Wire).
Specifications
Name | KJ-S130 | KJ-S230 |
---|---|---|
Fuel Type | Diesel | Diesel |
Phase | Single | Single |
Fuel Tank Capacity | 37 l | 68 l |
Operating Hours @Full Load | 7 hours | 8.8 hours |
Starting System | Electric | Electric |
Weight | 505 kg | 630 kg |
Sound Levels @7m | 75 dBA | 73 dBA |
Dimensions | 1488 x 650 x 971 mm | 1730 x 830 x 1046 mm |
Name | KJ-S130 | KJ-S230 |
---|---|---|
Engine Model | V2203 | V3300 |
Engine Type | Vertical Water Cooled | Vertical Water Cooled |
Displacement | 2197 cc | 3318 cc |
No of Cylinders | 4 | 4 |
Bore & Stroke | 87 x 92.4 mm | 98 x 110 mm |
Max Output | 20.1 kW | N/A |
Rated Output | 17.2 kW | 26.8 kW |
RPM | 1500 rpm | 1500 rpm |
Name | KJ-S130 | KJ-S230 |
---|---|---|
Type | Revolving Field | Revolving Field |
Rated Output | 12.5 kVA | 24 kVA |
Voltage | 240 | 240 |
Frequently | 50 Hz | 50 Hz |
Current | 52.1 Amps | 95.8 Amps |
Power Factor | 1 | 1 |
Poles | 4 | 4 |
Voltage Regulation | AVR | AVR |